44.2.6 Alarm History Show Command Example
The following example displays the historic critical level alarms for all alarm categories, and
all conditions.
44.2.7 Alarm History Clear Command Example
The following example removes the historic minor level alarms for all alarm categories, and
all conditions.
44.2.8 Alarm XEdit Command Example
The following example creates an alarm report entry that sets all system alarms to the major
severity level and sends them to an SNMP server at the local 3 log facility.
severity This is the alarm severity level (critical, major, minor or info).
clearable This displays “V” if the alarm clear command removes the alarm from the
system. It displays a dash (-)if the alarm clear command does not remove the
alarm from the system.
Table 99 Log Format (continued)
LABEL DESCRIPTION
ras> alarm history show critical all all all all rev detail
no alarm condition severity timestamp source
------ ------ ------------------------ -------- -------------- -------
1 eqpt +fan_err critical 07/28 15:23:35 eqpt
* IES-612-51:Fan 2 speed 0, low 2000, high 8000
2 eqpt +fan_err critical 07/28 15:23:35 eqpt
* IES-612-51:Fan 3 speed 0, low 2000, high 8000
3 eqpt +fan_err critical 07/28 15:23:33 eqpt
* IES-612-51:Fan 1 speed 0, low 2000, high 8000
ras> alarm history clear minor
ras> alarm xedit sys all major local3 syslog